Scientific Study: The Effect of Aluminum Surface Finish on Infrared Emissivity

Research conducted by P. M. Reynolds (1961)

In a scientific study published in the British Journal of Applied Physics in 1961, researcher P. M. Reynolds investigated how surface roughness and oxidation affect the infrared emissivity of aluminum.

The study, titled Spectral Emissivity of 99.7% Aluminium Between 200 and 540°C, compared polished, roughened, and anodized aluminum across infrared wavelengths ranging from 1 to 14 micrometers.

Experimental Findings: Polished vs. Roughened Aluminum

Reynolds reported the following spectral emissivity measurements:

Infrared wavelengthRoughened aluminumPolished aluminum
2 micrometers30%9%
8 micrometers24%4%

The differences were substantial:

At 2 micrometers:

  • Roughened aluminum: 30% emissivity.
  • Polished aluminum: 9% emissivity.
  • Reduction: 21 percentage points, representing a 70% relative reduction in emissivity.

At 8 micrometers:

  • Roughened aluminum: 24% emissivity.
  • Polished aluminum: 4% emissivity.
  • Reduction: 20 percentage points, representing an 83.3% relative reduction in emissivity.

What These Measurements Mean: Emission, Absorption and Reflection

Emissivity measures how effectively a material emits infrared radiation compared with an ideal blackbody at the same temperature and wavelength.

The significance of Reynolds’s findings is that polished aluminum exhibited substantially lower infrared emissivity than roughened aluminum.

Under the corresponding wavelength and thermodynamic conditions, Kirchhoff’s law relates a material’s spectral emissivity to its spectral absorptivity.

For an opaque surface, the relationship is:

Reflectance = 100% − Absorptivity

Using the corresponding spectral measurements, the following illustrates the relationship:

Infrared wavelengthSurfaceEmissivityCorresponding reflectance*
2 μmRoughened30%70%
2 μmPolished9%91%
8 μmRoughened24%76%
8 μmPolished4%96%

Reflectance values are inferred from emissivity using the opaque-surface and corresponding spectral-equilibrium assumptions; they were not separately reported as direct reflectance measurements in Reynolds’s abstract.

The experimental results demonstrate that aluminum surface roughness and oxidation have a substantial influence on infrared emissivity. The polished samples exhibited significantly lower emissivity than the roughened samples.

Scientific Conclusion

Reynolds’s 1961 research provides experimental evidence that aluminum surface condition significantly influences its infrared radiation properties.

At the measured wavelengths, polished aluminum demonstrated a 70% reduction in spectral emissivity at 2 micrometers and an 83.3% reduction at 8 micrometers compared with roughened aluminum.

These findings establish the importance of surface finish when evaluating the infrared emissivity, absorptivity, and reflective characteristics of aluminum.

Original Research Citation:

Reynolds, P. M. (1961). Spectral emissivity of 99.7% aluminium between 200 and 540°C. British Journal of Applied Physics, 12(3), 111–114.

DOI: 10.1088/0508-3443/12/3/306

Original Scientific Publication: https://doi.org/10.1088/0508-3443/12/3/306

Downloadable Research Data: https://thermomat.ehu.eus/ekhi/publication/1/